Medema Mini Crosser M1 Manuel d'utilisateur Page 10

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 9
Quick guide P9-0155-Q
10 of 16
Version 2.0.3/2013
Medema Production A/S
Battery indicator
If there is an electronic fault, a number of lamps in the battery indicator will
light up. The following table shows what they mean.
For further information on troubleshooting see the User Manual.
Lamps Causes Remedy
1 lamp The batteries need charging
or the connection to a battery
is poor.
Check all connections
between the controller and
batteries. If these are ne, try
charging the batteries
2 lamps Poor connection to the motor. Check the connection
between the motor and
controller. Contact supplier.
3 lamps Short-circuit between
the motor and a battery
connection.
Contact supplier - say how
many lamps are lit.
4 lamps Not in use
5 lamps Not in use
6 lamps The S180 is prevented
from driving. Inhibit 2 is
active. This may be due to
the battery charger being
connected, the plug to the
thermal switches being
disconnected, a fault in the
thermal switch or the scooter
is overheating.
The Mini Crosser will turn
itself off automatically after
it has been stationary for 10
minutes. The battery indicator
ashes with 6 lamps at a rate
of about 3 seconds.
Stop the unit and wait 3-5
minutes before restarting.
Turn the key to 0 and then to
1 to reset the fault.
Contact supplier.
To start M1 again, the key
must be turned to position 0
and back to I.
7 lamps Accelerator fault. Make sure that the
accelerator is in neutral when
the Mini Crosser is turned on.
8 lamps Controller fault. Contact supplier.